Description
Product Overview
The ETCR 2000A+ Loop Tester is a dedicated ground resistance meter designed for professionals who need accurate, repeatable measurements in demanding environments. It employs a loop‑resistance technique that combines voltage and current coils to calculate resistance using the formula R = E/I, delivering a high‑resolution reading as fine as 0.001 Ω across a range of 0.01 Ω to 200 Ω. The device is built around a rugged ABS housing that meets industrial durability standards, and its internal electronics are calibrated to maintain stability over a wide temperature span. With a compact clamp size of 65 mm × 32 mm, the tester can be positioned around conductors and grounding electrodes without the need for auxiliary electrodes, simplifying the testing process while preserving safety. The unit operates on four AA batteries, providing up to 30 hours of continuous use, and includes a clear LCD display that presents both numeric values and graphical bar indicators for quick visual assessment.
In addition to its core measurement capabilities, the ETCR 2000A+ offers a suite of auxiliary functions that enhance field productivity. Users can switch between resistance, voltage, and current measurement modes, allowing the instrument to serve as a versatile diagnostic tool for a variety of electrical systems. The device also features an automatic shut‑off function to conserve battery life, a built‑in data hold function for capturing transient readings, and a low‑battery warning that alerts the operator before power depletion becomes critical. All controls are ergonomically placed for one‑hand operation, and the device includes a detachable test lead set that can be stored in a dedicated compartment on the back of the unit.
Technical specifications are clearly listed on the product label and in the accompanying user manual. The meter’s accuracy is ±1 % of reading plus 0.01 Ω, and it complies with IEC 61010‑1 safety standards for measurement and control equipment. The device’s dimensions are 14.02 × 9.02 × 4.02 inches, and it weighs only 2.5 pounds, making it easy to transport in a standard tool bag or case. The ETCR brand has a reputation for reliable instrumentation, and the 2000A+ model continues that tradition with a design that balances precision, durability, and user‑friendly operation.
Overall, the ETCR 2000A+ Loop Tester is engineered to meet the needs of electricians, grounding specialists, and field engineers who require a dependable instrument for measuring ground resistance in power distribution networks, meteorological stations, oilfield installations, and other critical infrastructure. Its combination of high resolution, wide measurement range, battery‑powered portability, and loop‑resistance methodology makes it a standout choice for professionals seeking accurate grounding verification without the complexity of traditional two‑point methods.
![[Product front view showing all components]](https://www.genviro.store/wp-content/uploads/2026/06/c12190d3879d4c6482c185aba02aac20.jpg)
Usage
When deploying the ETCR 2000A+ in the field, users typically begin by selecting an appropriate loop size that matches the grounding electrode configuration. The loop can be formed by positioning the clamp around a grounding rod, a buried conductor, or a combination of conductors that create a closed circuit. Because the device does not require the removal of grounding leads, it can be used on live systems without interrupting service, which is especially valuable in power plant environments where downtime must be minimized.
In construction sites, the meter is frequently used to verify that temporary grounding systems meet regulatory standards before heavy equipment is operated. The compact clamp easily fits around rebar or grounding plates, and the battery‑powered design eliminates the need for external power sources, allowing technicians to perform checks quickly and safely. For oilfield applications, the loop tester can assess the integrity of grounding systems that protect against static discharge and lightning strikes, ensuring that safety protocols are upheld in remote locations.
Industrial facilities often employ the ETCR 2000A+ for routine maintenance of grounding networks that protect sensitive electronic equipment. By measuring the combined resistance of grounding bodies, the instrument helps identify corrosion, loose connections, or inadequate grounding that could lead to equipment failure or personnel hazards. The device’s data hold feature enables users to record readings for later analysis, and the results can be logged into maintenance management software for trend monitoring and compliance reporting.
Why Choose Us
Choosing the ETCR 2000A+ means selecting a product backed by a manufacturer with a long history of delivering high‑quality electrical testing equipment. ETCR’s commitment to precision engineering is reflected in the meter’s tight accuracy specifications and its adherence to international safety standards. Each unit undergoes rigorous factory testing, including temperature cycling, vibration, and electromagnetic interference assessments, to ensure reliable performance in harsh field conditions.
Customer support is a core component of the ETCR experience. Buyers receive access to a dedicated technical assistance hotline staffed by engineers who can provide guidance on proper measurement techniques, troubleshooting, and calibration procedures. In addition, the company offers a one‑year warranty that covers defects in materials and workmanship, and an optional extended service plan that includes on‑site calibration and firmware updates.
From a value perspective, the ETCR 2000A+ combines advanced functionality with a competitive price point, delivering a cost‑effective solution for organizations that need to equip multiple technicians with reliable ground resistance testing tools. The device’s battery‑operated design reduces operational costs, and its durable construction minimizes the need for frequent repairs or replacements, resulting in a lower total cost of ownership over the product’s lifecycle.
Key Features
- High‑resolution loop resistance measurement from 0.01 Ω to 200 Ω with 0.001 Ω steps for precise grounding verification.
- Compact 65 mm × 32 mm clamp fits tight spaces, eliminating the need for auxiliary electrodes.
- Battery‑powered operation using four AA cells, providing up to 30 hours of continuous use in the field.
- Durable ABS housing and IEC‑compliant safety design withstands harsh industrial environments.
- Dedicated technical support and one‑year warranty ensure reliable after‑sales service.
FAQ
What is the difference between loop resistance and traditional two‑point resistance measurement?
Loop resistance measures the combined resistance of the grounding system by creating a closed loop with voltage and current coils, which captures the true path that fault currents would follow. Traditional two‑point methods only measure the resistance between two points and can miss additional resistance introduced by the surrounding soil and connections, leading to less accurate results.
Can the ETCR 2000A+ be used on live systems?
Yes, the device is designed for use on energized circuits. Its loop‑resistance technique does not require disconnecting the grounding electrode, allowing technicians to perform measurements without interrupting service, provided that proper safety procedures are followed.
How often should the meter be calibrated?
For most field applications, annual calibration is sufficient to maintain accuracy within the specified ±1 % tolerance. However, if the instrument is subjected to extreme temperature changes, mechanical shock, or frequent high‑current testing, more frequent calibration may be advisable.
What accessories are included with the meter?
The package contains the ETCR 2000A+ unit, a set of test leads with alligator clips, a protective carrying case, a quick‑start guide, and a full user manual that details measurement procedures, safety guidelines, and maintenance instructions.
Is there software available for data logging?
ETCR provides optional PC software that can interface with the meter via a USB connection, allowing users to download measurement data, generate reports, and integrate results into existing asset management systems. The software is compatible with Windows operating systems and includes templates for regulatory compliance documentation.




Surface Resistance Meter plplaaoo 10³‑10¹⁰Ω
Reviews